Part Number Hot Search : 
00380 BU7233SF QC962 2N6075A AMC7584 E18CA 4732A RBV1000
Product Description
Full Text Search
 

To Download RACM40-05S Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  med-1 rev.: 1/2016 www.recom-power.com 40 watt enclosed & open frame case style single output ac/dc converter features regulated converters ? long 5 year warranty ? 2mopp/250vac ? suitable for built in class ii applications ? wide input voltage range (85-264vac) ? low leakage current (<75a) ? 5000m operation ? -40c to +85c operating temperature racm40 2mopp 250vac en-55011 (pending) en-55022 (pending) iec/en-60601 certifed ansi/aami es-60601 certifed description the racm40 is a compact 3.6x2.38 high effciency ac/dc power supply with 2xmopp safety approval for medical applications. these space saving enclosed power supplies have an universal input voltage range (85-264vac), 4kvac isolation, require no minimum load and can be used at ambient temperatures of between -40c and +85c. the 5v, 12v, 15v, 24v or 48v output voltages are fully protected and have tolerances of less than 0.2% over the entire input voltage range and less than 0.5% over the entire load range. the output voltage can be trimmed over a 10% range. the racm40 series is certifed to medical safety standard iec/es/en-60601-1 3rd edition and feature bf rated outputs with less than 75a leakage current. it has a built-in class b emi flter and comes with a 5 year warranty. selection guide part input output output effciency number voltage range voltage current typ. (vac) (vdc) (a) (%) RACM40-05S (1,2) 85-264 5 8.0 90 racm40-12s (1,2) 85-264 12 3.34 92 racm40-15s (1,2) 85-264 15 2.67 92 racm40-24s (1,2) 85-264 24 1.67 92 racm40-48s (1,2) 85-264 48 0.84 93 5 y e a r w a r r a n t y 5 e314885 connections (2) case style (1) output power output voltage s ingle model numbering racm40- __ s / __-__ examples: racm40-12s = 12vout, standard enclosed case racm40-48s/of = 24vout, open frame style racd40-15s/of-st = 15vout, open frame style with screw terminal connection notes: note1: case style: without suffx, standard enclosed case add suffx /of for open frame style note2: connections: without suffx, standard connection with connector with suffx -st connection with screw terminals
basic characteristics parameter condition min. typ. max. input voltage 85vac 100vdc (3) 230vac 264vac 370vdc input current 115vac, fulll load 230vac, full load 1.0a 0.5a inrush current 230vac 60a input power @ no load 0.11w input frequency range ac input 50/60hz 440hz (3) start-up time 1 second rise time 20ms hold up time 115vac, full load 25ms minimum load 0% operating frequency range 5vdc, 230vac others, 230vac 70khz 120khz output ripple and noise (measured @ 20mhz bw) 5vdc, 12vdc and 15vdc with 10f/25v mlcc 24vdc, with 1f/50v mlcc 48vdc, with 0.1f/100v mlcc 75mvp-p 75mvp-p 150mvp-p 20 10 40 30 70 60 50 80 90 100 load (%) efficiency (%) 86 84 88 90 92 94 85 20 40 60 80 100 125 100 115 130 145 160 175 264 input voltage (vac) % of full load 85 84 86 88 90 92 94 125 145 185 205 245 105 170 225 264 input voltage (v) efficiency (%) 20 0 60 40 80 100 load (%) deviation (%) -1 0 1 115vac 230vac 115vac 230vac 50% load 100% load ac/dc converter med-2 rev.: 1/2016 www.recom-power.com specifcations (measured at t a = 25c, 250vac, full load and after warm-up) effciency vs. load effciency vs. input voltage load vs. input voltage vout deviation vs. load racm40 series racm40-24 notes: note3: confrmed performance, but not covered in certifcates. 100vdc inpult voltage with derating.
environmental parameter condition value operating humidity non-condensing 5% to 95% rh temperature coeffcient 0.02% / c operating temperature range 115/230vac, with derating -40c to +85c operating altitude 5000m max. mtbf according to mil-hdbk-217f, full load, +25c 3010 x 10 3 hours ac/dc converter med-3 rev.: 1/2016 www.recom-power.com specifcations (measured at t a = 25c, 250vac, full load and after warm-up) racm40 series protections parameter condition value input fuse internal line and neutral 2x t3.15a / 250vac, slow blow type short circuit protection (scp) continuous, auto-recovery over load protection (olp) % of iout rated (hiccup) 145% typ. over voltage protection (ovp) % of vout nominal (latch off) 125% min / 140% max. isolation voltgage (2mopp insulation) i/p to o/p i/p to chassis, o/p to chassis working voltage 4kvac / 1 minunte 2.5kvac / 1 minute 250vac / continuous means of protection 2mopp leakage current 264vac 75a max. medical device classifcation type bf applied device internal clearance creepage i/p to o/p i/p to o/p 8mm min. 8mm min. isolation resistance 500vdc 100m w min. insulation grade reinforced insulation regulations parameter condition value set voltage accuracy 230vac, full load 1% line voltage regulation low line to high line, full load 0.2% load voltage regulation 0% to 100% load 10% to 90% load 5vdc others 5vdc others 0.7% 0.5% 0.6% 0.4% output voltage trim on-board trimpot. 10% transient peak deviation load step from 50% - 75% change at 2.5a/s 3% vout max. transient recovery time load step from 50% - 75% change at 2.5a/s 500s typ. -40 100 80 85 75 50 60 40 20 0 -20 0 20 40 60 80 100 ambient temperature (c) output current (%) -40 100 80 85 50 60 40 20 0 -20 0 20 40 60 80 100 ambient temperature (c) output current (%) derating graph RACM40-05S(/of) racm40-12,15,24,48s(/of)
ac/dc converter dimension and physical characteristics parameter type value package dimension (lxwxh) enclosed case open frame 91.4 x 60.5 x 33.3mm 76.2 x 50.8 x 26.5mm package weight enclosed case open frame + -st version 169g 154g case material enclosed case aluminum continued on next page 76.2 fc 41.3 33.3 1.20 10.0 10.4 60.5 14.3 fc 84.2 91.4 3.5 con1 con2 51.3 m3 screws logo embossed trim adj. med-4 rev.: 1/2016 www.recom-power.com specifcations (measured at t a = 25c, 250vac, full load and after warm-up) racm40 series ac input connector con1 pin1 line pin3 neutral pin connector: molex kk156 dc output connector con2 pin1,2 -vout pin3,4 +vout pin connector: molex kk156 tolerance: 0.5mm fc: fxing center dimension drawing enclosed case (mm) safety and certifications certifcate type report / file number standard iec/en medical safety (cb scheme) 151101302 iec60601-1, 3rd edition, 2012 en60601-1, 3rd edition, 2014 ansi/aami medical safety es60601-1, 2012 risk managment 151101301_2037 iso 14971:2007 en iso 14971:2012 emc compliance condition standard / criterion emi standard en55011 + en55022 + fcc18, class b esd radiated immunity fast transient surge conducted immunity power frequency magnetic field air 8kv; contact 6kv 20v/m 2kv l-n 1kv and l-gnd/n-gnd 2kv 20vr.m.s 10a/m en61000-4-2, criteria a en61000-4-3, criteria a en61000-4-4, criteria a en61000-4-5, criteria a en61000-4-6, criteria a en61000-4-8, criteria a harmonic current full load en61000-3-2, class a voltage flicker en61000-3-3 shock iec60068-2-27 vibration iec60068-2-6 dip and interruptions, 230vac 50hz 30% 500ms 60% 100ms >95% 10ms >95% 5000ms en60601-1-2, criteria a en60601-1-2, criteria a en60601-1-2, criteria a en60601-1-2, criteria b top view
continued on next page 76.2 fc 41.3 33.3 1.20 10.0 10.4 60.5 14.3 fc 84.2 91.4 3.5 con1 con2 51.3 m3 screws logo embossed trim adj. ac/dc converter med-5 rev.: 1/2016 www.recom-power.com specifcations (measured at t a = 25c, 250vac, full load and after warm-up) racm40 series dimension drawing open frame (/of) (mm) fc 69.8 fc 44.4 con1 con2 50.8 24.0 2.5 1.6 trim adj. 10.0 44.0 76.2 ?3.2 ac input connector con1 pin1 line pin3 neutral pin connector: molex kk156 dc output connector con2 pin1,2 -vout pin3,4 +vout pin connector: molex kk156 tolerance: 0.5mm fc: fxing center top view side view side view bottom view
ac/dc converter med-6 rev.: 1/2016 www.recom-power.com specifcations (measured at t a = 25c, 250vac, full load and after warm-up) racm40 series screw terminal connection -st enclosed version open frame version the product information and specifcations are subject to change without prior notice. recom products are not authorized for use in safety-critical applications (such as life support) without recoms explicit written consent. a safety-critical application is defned as an application where a failure of a recom product may reasonably be expected to endanger or cause loss of life, infict bodily harm or damage property. the buyer shall indemnify and hold harmless recom, its affliated companies and its representatives against any damage claims in connection with the unauthorized use of recom products in such safety-critical applications. 14.3 con1 con2 51.3 logo embossed trim adj. con1 con2 trim adj. 14.3 con1 con2 51.3 logo embossed trim adj. con1 con2 trim adj. connector version screw terminal version ?-st? 14.3 con1 con2 51.3 logo embossed trim adj. con1 con2 trim adj. 14.3 con1 con2 51.3 logo embossed trim adj. con1 con2 trim adj. connector version screw terminal version ?-st? ac input connector con1 pin1 line pin3 neutral screw terminal: etb30 dc output connector con2 pin1,2 -vout pin3,4 +vout screw terminal: etb30 tolerance: 0.5mm fc: fxing center packaging information parameter type value packaging dimension (lxwxh) cardboard box enclosed case 111.0 x 94.0 x 51.0mm open frame 120.0 x 80.0 x 85.0mm packaging quantity 1pcs storage temperature range -40c to +85c


▲Up To Search▲   

 
Price & Availability of RACM40-05S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X